Subjects of training
( Note: Each subject is for an average of 2 hours)
1. Basic design criteria of an LV electrical installation (IS 732).
-
Protection against electric shock
-
Protection from thermal effect (fire due to short circuit)
-
Protection from over current & short circuit
-
Protection from over voltages
-
Selection of equipment
-
Safety services
2. Earthing Part 1 (IS3043 & IS732)
-
System earthing & safety in each network
-
Equipment earthing
-
Protective Equipotential Bonding & Protective conductors
3. Earthing Part 2 (IS3043 & IS732)
-
Sizing of conductors for earthing
-
Interpretation of IS3043
-
Reading and understanding CEA safety regulations (Measures relating to safety and electric supply 2010)
4. Earthing Part 3 (IEEE 142 & IEEE 1100)
-
UPS earthing
-
Earthing of electronic equipment
5. Earthing Part 4: (IS732)
-
Functional Earthing
-
Telecommunication bonding networks, design and testing criteria
6. Inspection and testing of an electrical installation (IS 732).
-
Basics of inspection
-
Subjects & methods of inspection
-
Reasons for inspection
-
Subjects of testing
-
Methods of testing with videos.
-
Periodic testing
7. Electrical safety in healthcare facilities and protection from shock (IS 732 & IS 17512).
-
Need for special requirements in Hospitals
-
Electrical system in general locations and special locations
-
Safety in general locations
-
Safety in special locations (patient safety and ignition of fire from electricity)
-
Need for inspection and verifications
8. Solar PV installation (IS732, IS 16997 / IEC 60364-7-712)
-
Protection for safety in special location
-
Lightning Protection
-
Earthing
-
Inspection and Testing
9. Lightning Protection Part 1 (IS/IEC 62305)
-
Analysis
-
Risk Assessment
-
Designing of Air termination
-
Designing of Down Conductors
-
Designing of Earth Termination
10. Lightning Protection Part 2 (IS/IEC 62305)
-
Separation Distance Calculations
-
Selection of components of LPS
-
Testing and quality requirements
-
Inspection and Verification
11. Surge Protective Device (SPD’s) Part 1 (IEC 61643-11/12 - IS16463 - 11/12).
-
SPD's - What are they
-
Voltage impulse withstand of equipment
-
Lightning Protection Zone (LPZ)
-
Requirements at each LPZ
-
Equipotential Bonding
-
Requirement and selection of Power Line SPD's based on LPZ
12. Surge Protective Device (SPD’s) Part 2 (IEC 61643-11/12 - IS16463 - 11/12) & IEC 61643-21/22
-
Power line SPD's selection based on IS732 (IEC 60364-5-53)
-
Selection of back up fuse
-
Selection based on priority to continuity of supply or continuity of protection
-
SPD's for Signaling and Telecommunication application basic requirements
-
Performance requirement and testing methods
-
Selection and erection of Telecom and Signal SPD's
Additional subjects
1. Training of trainers
-
Special training for people who are interested in training others.
-
Information about various national and international standards
-
Internationally accepted methods on electrical safety
-
Applicable areas of various safety and reliability measures in an installation
-
Myths and facts of safety and earthing.
2. Understanding NEC, IS732, IS3043 & CEA regulations, scope, contents, application.
-
Subjects of the standards,
-
Interpretation of various clauses
-
Explanation about drawings, tables annexures
3. Special Subjects
-
Non-standard Lightning Protection System
-
Lightning physics and basics of striking distance
-
Lightning protection of HV and Sub stations
-
Power quality and Mitigation techniques
-
New & emerging technologies in electrical engineering (eg. LVDC)